ORIGINAL ARTICLE
Dissolution of silicic acid from amosite and quartz dusts under physiological conditions.
,
 
,
 
 
 
More details
Hide details
 
Publication date: 1975-06-01
 
 
Scand J Work Environ Health 1975;1(2):117-119
 
KEYWORDS
ABSTRACT
The dissolution of silica from amosite dust in human serum and in Ringer buffer at 37 degrees C was found to be significantly higher than that from quartz. The significance of this finding in relation to their fibrogenic effects has been discussed.