%0 Journal Article %T Sampling and analysis of hexavalent chromium during exposure to chromic acid mist and welding fumes. %A Blomquist, G. %A Nilsson, C. A. %A Nygren, O. %J Scandinavian Journal of Work, Environment & Health %D 1983 %8 December 9 %N 6 %@ 0355-3140 %F Blomquist1983 %X

Sampling and analysis of hexavalent chromium during exposure to chromic acid mist and welding fumes. Scand j work environ & health 9 (1983) 489-495. In view of the serious health effects of hexavalent chromium, the problems involved in its sampling and analysis in workroom air have been the subject of much concern. In this paper, the stability problems arising from the reduction of hexavalent to trivalent chromium during sampling, sample storage, and analysis are discussed. Replacement of sulfuric acid by a sodium acetate buffer (pH 4) as a leaching solution prior to analysis with the diphenylcarbazide (DPC) method is suggested and is demonstrated to be necessary in order to avoid reduction. Field samples were taken from two different industrial processes-manual metal arc welding on stainless steel without shield gas and chromium plating. A comparison was made of the DPC method, acidic dissolution with atomic absorption spectrophotometric (AAS) analysis, and the carbonate method. For chromic acid mist, the DPC method and AAS analysis were shown to give the same results. In the analysis of welding fumes, the modified DPC method gave the same results as the laborious and less sensitive carbonate method.

%R 10.5271/sjweh.2384 %U https://www.sjweh.fi/show_abstract.php?abstract_id=2384 %U https://doi.org/10.5271/sjweh.2384 %P 489-495