Original article

Scand J Work Environ Health 1981;7(1):56-61    pdf

https://doi.org/10.5271/sjweh.2565 | Issue date: Mar 1981

Interferences in the spectrophotometric S-diphenylcarbazide determination of environmental hexavalent chromium in a chromium and zinc plating plant.

by Carelli G, La Bua R, Rimatori V, Porcelli D, Iannaccone A

A study on the determination of environmental hexavalent chromium [Cr(VI)] was carried out in a chromium and zinc plating plant. The atmospheric particulate was collected both on glass wool filters and with an electrostatic sampler; Cr(VI) was determined by the S-diphenylcarbazide method. The filtered and electrostatically collected Cr(VI) was extracted with both 1.4% sulfuric acid and 7% sodium carbonate. Strong interference was observed when extraction was carried out with the acid medium. Alkaline extraction permits 95 +/- 6 (+/- SD)% recovery of the total chromium and has been shown to be suitable in releasing Cr(VI). The analyses of the alkaline samples were carried out with the standard addition method to compensate for a depressive interference of 26 +/- 8 (+/- SD)%. The absorbance decrease of the Cr-S-diphenylcarbazide complex is a time function, and it should be measured within a few minutes of the reagent addition.